NOTICE OF SOLICITATION STATEMENT OF PRE-QUALIFICATION
Notice Subject(s)
Construction
Notice Type(s)
Notice
Event Start Date & Time
September 3, 2014 09:29 AM
Event End Date & Time
September 19, 2014 05:00 PM
Event Deadline Date & Time
09/19/14 05:00 PM
Description/Agenda
KEARNS IMPROVEMENT DISTRICT
NOTICE OF SOLICITATION
STATEMENT OF PRE-QUALIFICATIONS
Kearns Improvement District is seeking contractors that would like to pre-qualify to submit bids for the construction of its 5 MG Culinary Water Tank and 30-Inch Diameter Waterline Project.
PROJECT DESCRIPTION: The construction of a water-tight reinforced concrete structure with a 5 million gallon capacity; valve vault with piping, valves, etc.; 30-inch diameter inlet/outlet piping; site work; grading, and emergency overflow piping and structures. The project also includes electrical connections to and electrical work associated with the valve vault at the tank site.
REQUIRED QUALIFICATIONS: The qualifying contractors must:
1) Show a minimum of 5-years of experience installing reinforced concrete culinary water reservoirs.
2) Demonstrate construction of at least three (3) reinforced concrete culinary water tanks with a capacity of 3 Million Gallons or larger and construction of at least three (3) culinary waterlines 18 inches in diameter or larger within City Streets in the last 10 years.
3) Demonstrate construction of at least three (3) reinforced concrete culinary water reservoirs with a capacity of 3 Million Gallons or larger in the last 10 years.
4) Document completion of three (3) separate projects with a minimum cost of $1,000,000 each. The total value of change orders for each of these projects must equal less than 10% of the total project cost.
5) Demonstrate through references satisfactory performance on similar projects.
6) Have a local office within the State of Utah.
7) Provide a minimum of 5 references.
8) Show capability to meet the OWNER?S insurance and bonding requirements.
Only Contractors who are pre-qualified by Kearns Improvement District will be allowed to submit bids for the project.
STATEMENTS OF PRE-QUALIFICATIONS: Must be received by 5:00 p.m., Friday, September 19, 2014 at Kearns Improvement District Office, 5350 West 5400 South, Kearns, Utah 84118
PRE-QUALIFICATION PACKETS are available from the Engineer (Hansen, Allen & Luce, Inc., 6771 South 900 East, Midvale, Utah 84047, 801-566-5599 Vern Conder).
Kearns Improvement District reserves the right to accept or reject any or all bids, or any part of any bid, to waive any informalities in any bid as its best interest appear.
KEARNS IMPROVEMENT DISTRICT
NOTICE OF SOLICITATION
STATEMENT OF PRE-QUALIFICATIONS
Kearns Improvement District is seeking contractors that would like to pre-qualify to submit bids for the construction of its 5 MG Culinary Water Tank and 30-Inch Diameter Waterline Project.
PROJECT DESCRIPTION: The construction of a water-tight reinforced concrete structure with a 5 million gallon capacity; valve vault with piping, valves, etc.; 30-inch diameter inlet/outlet piping; site work; grading, and emergency overflow piping and structures. The project also includes electrical connections to and electrical work associated with the valve vault at the tank site.
REQUIRED QUALIFICATIONS: The qualifying contractors must:
1) Show a minimum of 5-years of experience installing reinforced concrete culinary water reservoirs.
2) Demonstrate construction of at least three (3) reinforced concrete culinary water tanks with a capacity of 3 Million Gallons or larger and construction of at least three (3) culinary waterlines 18 inches in diameter or larger within City Streets in the last 10 years.
3) Demonstrate construction of at least three (3) reinforced concrete culinary water reservoirs with a capacity of 3 Million Gallons or larger in the last 10 years.
4) Document completion of three (3) separate projects with a minimum cost of $1,000,000 each. The total value of change orders for each of these projects must equal less than 10% of the total project cost.
5) Demonstrate through references satisfactory performance on similar projects.
6) Have a local office within the State of Utah.
7) Provide a minimum of 5 references.
8) Show capability to meet the OWNER?S insurance and bonding requirements.
Only Contractors who are pre-qualified by Kearns Improvement District will be allowed to submit bids for the project.
STATEMENTS OF PRE-QUALIFICATIONS: Must be received by 5:00 p.m., Friday, September 19, 2014 at Kearns Improvement District Office, 5350 West 5400 South, Kearns, Utah 84118
PRE-QUALIFICATION PACKETS are available from the Engineer (Hansen, Allen & Luce, Inc., 6771 South 900 East, Midvale, Utah 84047, 801-566-5599 Vern Conder).
Kearns Improvement District reserves the right to accept or reject any or all bids, or any part of any bid, to waive any informalities in any bid as its best interest appear.
http://kearnsid.org/prequalify_5mg.pdf
Notice of Special Accommodations (ADA)
If you are planning to attend this public meeting and, due to a disability, need assistance in understanding or participating in the meeting, please notify the District two (2) days or more in advance of the meeting and we will try to provide whatever assistance may be required. The person to contact is Pamela Gill, 801-968-1011.
Notice of Electronic or Telephone Participation
A member of the Board of Trustees may participate telephonically.